99无码不卡中文字幕在线视频_理论国产无码在线_久久综合国产乱子伦精免费_国产传媒日韩欧美成人动漫精品免费观看

產(chǎn)品中心

小鼠醛固酮(ALD)酶聯(lián)免疫吸附檢測試劑盒
一鍵復制產(chǎn)品信息
ELK11272
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00
96T*5 ¥13600.00

Overview

Product name: Mouse ALD(Aldosterone) ELISA Kit
Reactivity: Mouse
Alternative Names: ALD
Assay Type: Competitive Inhibition
Sensitivity: 9.41 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Metabolic pathway;Endocrinology;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse ALD. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ALD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ALD in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
2000.00 0.189
1000.00 0.427
500.00 0.596
250.00 0.933
125.00 1.169
62.50 1.583
31.25 1.799
0.00 2.213

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ALD and the recovery rates were calculated by comparing the measured value to the expected amount of ALD in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ALD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-95% 96-105% 85-96% 90-99%
EDTA plasma(n=5) 82-96% 95-102% 87-98% 81-97%
Heparin plasma(n=5) 86-93% 93-101% 85-98% 90-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉